English
???????
??
   
 



The Battery Simulator (BS) consists of a power supply as a load independent voltage source. To simulate the characteristic curve of a battery, the power supply can be adjusted while running the test program. The battery type, the battery capacity and the battery condition (age, temperature) can be simulated as well due to the adjustability of the resistance. Like real batteries with different open circuit voltages the BS can also adjust the open circuit voltage.

A 32 Bit digital signal processor ensures high speed control and data aquisition. A variety of options are available such as additional input channels, CAN-Bus interface and the RS232 interface to temperature chamber.


The simplified theoretical model of a battery is used to adjust DC
output voltage of the Battery Simulator.

 

 

The test system consisting of battery simulator BS and the software BTS 600 can replace real batteries in numerous applications.
Typical applications are test bench lines for combustion engines and electric drive systems.

Control interface:

MBT

PC software:

BTS-600

External control:

Analogue Input, CAN-Bus, RS-232

Resolution:

± 15 Bit

Data Acquisition Rate:

10 ms

Accuracy:

± 0.25% Full Scale

DC current ripple:

≤ 1% Full Scale

Current rise time (10-90% load) I:

< 5 ms

Current rise time (10-90% load) U:

< 20 ms

Input power supply:

3-phase, 50/60 Hz

Ambient temperature:

10-40 °C (50-104 °F)

Model
Designation

Imax
[A]

UImax
[V]

Umax
[V]

Cabinet
Size

BS 150-500/40 kW

150

265

500

I 1

BS 220-500/40 kW

220

180

500

I 1

BS 330-500/40 kW

330

120

500

I 1

BS 150-500/60 kW

150

400

500

I 1

BS 220-500/60 kW

220

270

500

I 1

BS 330-500/60 kW

330

180

500

I 1

BS 300-500/80 kW

300

265

500

I 2

BS 450-500/80 kW

450

175

500

I 3

BS 600-500/80 kW

600

130

500

I 3

BS 300-500/120 kW

300

400

500

I 3

BS 450-500/120 kW

450

265

500

I 3

BS 300-500/160 kW

300

530

500

I 4

BS 450-500/160 kW

450

355

500

I 4

BS 600-800/240 kW

600

400

800

I 5

BS 600-800/480 kW

600

800

800

I 6

Other current and voltage ranges available on request.

Size

Dimensions (HxWxD) [mm]

I 1

2200 x 800 x 800 (86.7'' x 31.5'' x 31.5'')

I 2

2200 x 1000 x 1000 (86.7'' x 39.4'' x 39.4'')

I 3

220 x 1600 x 800 (86.7'' x 63'' x 31.5'')

I 4

2200 x 2000 x 1000 (86.7'' x 78.8'' x 39.4'')

I 5

2200 x 3000 x 800 (86.7'' x 118.2'' x 31.5'')

I 6

2200 x 6000 x 1200 (86.7'' x 236.3'' x 47.5'')

  • Additional Voltage, Temperature, Analog Inputs
  • I/O for Auxiliary Devices, RS-232, CAN Interface
  • Paralleling of Units